Biochrom ASYS microplate readers are ideal for easy applications, scanning and kinetics (even with magnetic stirrer). They have front loading to allow easy integration with robotic systems. There is a wide variety of software available in Windows® both for data acquisition and instrument control, as well as for data reporting. Readers are implemented with the automatic check-in function for quick and efficient calibration. Quality Control Plates are available.
EZ READ 400 MICROPLATE READER RANGE WITH FILTER TECHNOLOGY IN THE RANGE OF 400-750 nm,
CONTROLLED BY GALAPAGOS SOFTWARE
Ideal DETECTOR for laboratories that require a practical instrument, it is robust for absorbance tests in routine applications. EZ Read 400 is available in two versions:
EZ READ 400 ELISA complete with 4 filters (405, 492, 450, 620 nm)
Dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB
EZ READ 400 RESEARCH with 8 filters (405, 492, 450, 620 nm / 570, 595, 562, 650 nm)
The most flexible instrument, dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB. It provides greater versatility by offering the opportunity to determine total protein (including Bradford, BCA, Lowry) and cell growth experiments (including MTT, XTT, cell density)
The EZ Read 400 microplate detectors are controlled by PC using the
new Galapagos software created by Biochrom to simplify data acquisition and analysis.
EZ READ 800 MICROPLATE DETECTOR RANGE WITH FILTER TECHNOLOGY, IDEAL FOR FASTER ANALYSES,
CONTROLLED BY GALAPAGOS SOFTWARE
Ideal detector for laboratories that require maximum speed and convenience in absorbance analysis during routine applications. The analysis time is approximately 5 seconds to read a 96-well plate. Connection via USB 2.0, automatic calibration. EZ Read 800 is available in two versions:
EZ READ 800 ELISA complete with 4 filters (405, 492, 450, 620 nm)
Dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB
EZ READ 800 RESEARCH with 8 filters (405, 492, 450, 620 nm / 570, 595, 562, 650 nm)
The most flexible instrument, dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB. It provides greater versatility by offering the opportunity to determine total protein (including Bradford, BCA, Lowry) and cell growth experiments (including MTT, XTT, cell density)
The EZ Read 800 microplate detectors are controlled via PC using the new Galapagos software designed by Biochrom to simplify data acquisistion and analysis.
EZ READ 800 Plus MICROPLATE DETECTOR RANGE WITH FILTER TECHNOLOGY, IDEAL FOR FASTER ANALYSES,
CONTROLLED BY KEYBOARD AND INCORPORATED SOFTWARE; CONTROL OPTION VIA GALAPAGOS SOFTWARE
Ideal detector for laboratories that require maximum speed and convenience in absorbance analysis during routine applications. The detectors can be controlled via keyboard and incorporated software; the data is displayed in the built-in display and is the ideal choice for those not wanting to use a PC. Alternatively, you can always use the Galapagos software. The analysis time is approximately 5 seconds to read a 96-well plate. Connection via USB 2.0, automatic calibration. EZ Read 800 Plus is available in two versions:
EZ READ 800 Plus ELISA complete with 4 filters (405, 492, 450, 620 nm)
Dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB
EZ READ 800 Plus RESEARCH with 8 filters (405, 492, 450, 620 nm / 570, 595, 562, 650 nm)
The most flexible instrument, dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB. It provides greater versatility by offering the opportunity to determine total protein (including Bradford, BCA, Lowry) and cell growth experiments (including MTT, XTT, cell density)
The EZ Read 800 Plus microplate detectors are controlled via PC using the
new Galapagos software
designed by Biochrom to simplify data acquisistion and analysis.
Ideal detector for laboratories that require maximum speed and convenience in absorbance analysis during routine applications. The LED technology together with high-quality interference filters provides fast, uncompromising measurements in terms of sensitivity, accuracy and reproducibility. The models with LED technology provide measurements in the UV region up to 340 nm. Control with the Galapagos software. The analysis time is approximately 5 seconds to read a 96-well plate. Connection via USB 2.0, automatic calibration. EZ Read 800 LED is available in two versions:
EZ READ LED complete with 4 filters (405, 490, 450, 620 nm)
Dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB
EZ READ LED UV complete with 5 filters (340, 405, 490, 450, 620 nm)
The most flexible instrument, dedicated to the main ELISA applications including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB. It provides greater versatility by offering a 340 nm filter for NADH / NADPH measurements
The EZ Read LED microplate detectors are controlled via PC using the
new Galapagos software designed by Biochrom to simplify data acquisistion and analysis.
EZ READ 2000 MICROPLATE DETECTOR RANGE FOR SCANS WITH MONOCHROMATOR, FAST, ACCURATE ANALYSIS
WITH DIFFERENT SIZE PLATES, CONTROL VIA GALAPAGOS SOFTWARE
Ideal detector for laboratories requiring maximum usage flexibility, speed and convenience in absorbance analysis, perfect for all application methods. The detector is highly versatile and it can read different plate formats (12-, 24, 48- and 96-well) and provide rapid, uncompromising measurements in terms of sensitivity, accuracy and reproducibility. Thanks to optics with monochromator, it can read any wavelength in the measuring range of 340-800 nm, and you can obtain the spectrum of the entire measuring range. Control with the Galapagos software. Connection via USB 2.0, automatic calibration.
EZ READ 2000 microplate detector with optical monochromator; measuring range 340-800 nm, software to obtain the spectrum on the entire measuring range.
The most versatile and flexible tool, dedicated to every possible application in routine research. ELISA analysis including NPP, ABTS, OPD, Slow TMB, TMB turbo, ultra TMB. Determination of the total proteins (including Bradford, BCA, Lowry). Cell growth experiments (including MTT, XTT, cell density) and cell survival. Software for the acquisition of kinetics, absorption readings at 340 nm (NADH), Peak Purity, maximum peak absorbance. Shaking function.
The EZ Read LED microplate detectors are controlled via PC using the new Galapagos software designed by Biochrom to simplify data acquisistion and analysis.
AVAILABLE WASHER AND INCUBATORS
HEADQUARTERS
Via Roma, 18 - 20072 Pieve Emanuele (MI)
+39 02 90724336
OPERATIONAL HEADQUARTERS
Via Robinie, 21 - 20073 OPERA (MI)
OPENING HOURS
P.I. 05102590154